2

 

TRIM V8.3.


Current Fix Level: E

Current Zap Level: N/A

Current Version: 8.3.2

Fixes

FIX

EXPLANATION

A Various errors including abends in the ADABAS link routine (ADALNK, ADACICS) if TRMUEX1G and TRMUEX2G active as Link-Exit-1 routines.
Reference 31144, 31191
B

Allow mulitple TRMRSP definitions with same RSP but different subcode.
Reference 31269

CLOG buffers (FB, RB, etc.) incorrectly displayed in DETAIL reports.
Reference 31298

Hour and PRESUM accumulators incorrect.
Reference 31307

C

Various errors including abend in TRMUEX4*
with CLOGLAYOUT=8 and EVENTLOG records.
Reference 31332

TRMLOG SB and CLOGLAYOUT=8
All commands written to CLOG independent of SB supplied or not.
Reference 31339

A value of '**' is incorrectly displayed for the Session Statistics Print Frequency on the CTAR screen.
Reference 31339

HOUR accumulators not rolling to next hour on time
(also may impact PRESUM, TRMTAP and SESSION printing).
Reference 31342

PRESUM SUMMARY
IO, DUR, CPU values incorrect.
Reference 31355

QUQF information incomplete.
Reference 31359

SESSION statistics PRINTING does not take place or at wrong time
CTAQ display in RTM for PRINT FREQ ff incorrect.
Reference 31370

D

HEADING, HEADING2 and FIELD names not printed in SUMMARY reports
Reference 31384

Write a copy of data written to DDPRINT (statistics, etc.) to a separate dataset. Usefull if DDPRINT is directed to disc, where the file is not available before close.
Reference 31388

DUR, CPU value incorrect for PRESUM reports
DEC. POINT missing
Fields of TYPE=U incorrect (PLOG)
Reference 31476

LOG=YES in TRMTAP only passes the basic record to CLOG, all buffer records (FB, RB, etc.) are surpressed.
Reference 31514

Errors if running under ADABAS 8.1
Reference 31539

Certain combinations of TRMLOG settings may cause logging to be suppressed.
Reference 31615

USER/INTERNAL commands incorrect in session statistics running under ADABAS 8.3
Reference 31622

Allow RTM and UEX4/UEX11 communication runs in an ADABAS VISTA environment without having to define Origin CID transport : ACBUSER
Reference 31632

PLOG records written to TRMOUT* without matching FNR of SHOW
Incorrect CONTROL FIELD VALUE in sub-totals of SUMMARY report

Reference 31642

PRESUM records extracted from SMF via TRMSMFEX did not show the local date/time (STCK #2) when the records has been written to SMF
Reference 31712

NAT3022 error with the TRIM Natural Monitor logging
Reference 31488

Problems using the START option on the various Summary screens.
Reference 31463, 31464

E

Support for ADABAS 8.4
Reference 31463, 31464

DISPLAY and SHOW output lines not separated by a blank line
In Detail report with INPUT=PROTECTION part of last display line repeated
Reference 31741

ASRA with ADATRUE under CICS TS 2.1 (420)
Reference 31777 (VSE only)

QUQF information incomplete if maximum users fitting in record buffer reached
Could cause buffer overwrite
Reference 31955 (VSE only)

CLOG RECORDS MISSING IF LOG=YES AND TRMLOG SETTINGS IN PLACE
Reference 31959

UNPACKED FIELDS IN PLOG WITH NEGATIVE VALUE INCORRECT IN SHOW/OUTPUT
Reference 32046

MINIMUM/MAXIMUM/AVERAGE OF DATETIME/DATE4TIM INCORRECT
Reference 32276

Allow jobstep to be propagated to clog.
As a temporary (|||) solution the jobstep will be shown in Trim batch reports using field name "ADD6".
TRMUEX4* must be customized to use the jobname from the userinfo area. this is achieved either by setting ALTJN=S in TRMTAP or apply customization zap "USE COMMAND QUEUE JOB NAME" at location X'38' with REP E2
Reference 32297

CPU calculation incorrect in detail/summary with CLOGLAYOUT=8
NOTE: CPU calculation based on the formulas provided by Software AG has the length of the format buffer as one variable.
With CLOGLAYOUT=8 this information is no longer provided as part of the Adabas Control Block.
Because of that LOGFB=YES becomes mandatory if CPU time should be extracted from the CLOG records.
Any logging customization via TRMLOG and/or COMM4 runs has to make sure, that the format buffer is passed through.
Reference 32333

No update level shown on the ENIN screen.
Reference 31974

TNMA001P program to reset the TNM Password.
Reference 32310

TRMCMD Trim Command Display tool for Debugging.
Reference 32176